Hi guys & gals,
I have a load for my FTR gun with Lapua 155 scenars :
47.72 gr - Varget (*Compressed load)
OAL from ogive - 2.231
Backed off 12 thou of the lands
Federal 210M primers
But Now all I can get are Fedral 215M primers is there any one using these magnum primers in such a load or should I scratch it and start a new development load???
Primer issue
Moderator: dromia
Forum rules
All handloading data posted on Full-Bore UK from 23/2/2021 must reference the published pressure tested data it was sourced from, posts without such verification will be removed.
Any existing data without such a reference should be treated as suspect and not used.
Use reloading information posted here at your own risk. This forum (http://www.full-bore.co.uk) is not responsible for any property damage or personal injury as a consequence of using reloading data posted here, the information is individual members findings and observations only. Always verify the load data and be absolutely sure your firearm can handle the load, especially older ones. If in doubt start low and work your way up.
All handloading data posted on Full-Bore UK from 23/2/2021 must reference the published pressure tested data it was sourced from, posts without such verification will be removed.
Any existing data without such a reference should be treated as suspect and not used.
Use reloading information posted here at your own risk. This forum (http://www.full-bore.co.uk) is not responsible for any property damage or personal injury as a consequence of using reloading data posted here, the information is individual members findings and observations only. Always verify the load data and be absolutely sure your firearm can handle the load, especially older ones. If in doubt start low and work your way up.
Re: Primer issue
You have changed a component of your load and therefore should work up the load again. I would start at 5% lower than your normal load. You may find that the magnum primer significantly changes the velocity/pressure for a given charge of powder compared to the 210gm primer.
Steve E
Steve E
Re: Primer issue
Certainly work up by at least 5% and in an ideal world hold out for Fed210M, as an alternative see if you can find some CCI BR - I have found them to be very close to the Fed210M
Re: Primer issue
I had planned on backing off to 45 gr. to allow for the hotter faster burn of the magum primer... as I'm new to this , I just said I'd check.
sign92
Thanks Lads. to those who contacted me off thread too! :goodjob:
sign92
Thanks Lads. to those who contacted me off thread too! :goodjob: